Online UPS 1Ph-1Ph

Capacity Range3KVA to 15KVA
Phase1-1 Phase
EfficiencyUp to 94%
Technology UsedDigital Signal Processing
THD<2% (linear load), <5% (non-linear load)
Transient Time0ms (From Mains load to Battery mode)
Output Power Factor0.9 to unity
DisplayInteractive LCD Display

Reliable Power Protection with Three-Phase Online UPS Systems

Our UPS systems ensure overload protection, safeguarding against power surges, and short circuit protection to prevent electrical faults. With 94% efficiency, they minimize energy loss and operational costs. Plus, our extensive product range offers versatile solutions for diverse power needs.

Overload Protection

Automatically adjusts to prevent damage from power surges or excessive demands, guaranteeing both equipment safety and uninterrupted operations.

Short Circuit Protection

Immediately detects and isolates electrical short circuits, preventing potential damage to the UPS and connected equipment, ensuring uninterrupted power supply.

Efficiency

At Enventa, our UPS systems boast an impressive 94% efficiency, ensuring minimal energy loss and reduced operational costs while maintaining optimal performance.

Extensive Product Range

Our extensive product range covers a power spectrum from 40kVA to 250kVA, offering versatile UPS solutions that cater to diverse needs.

The Enventa 1-Phase In, 1-Phase Out Online UPS is a high-performance, double-conversion uninterruptible power supply designed to provide uninterrupted, clean, and regulated power to critical loads. Built with advanced Digital Signal Processing (DSP) technology, it ensures precise voltage regulation, high efficiency, and superior power protection.

The pure sine wave output ensures compatibility with all types of sensitive electronic equipment. The UPS operates over a wide input voltage and frequency range, making it suitable for environments with unstable grid conditions. Additionally, the intelligent battery management system optimizes charge and discharge cycles, extending battery life and preventing overcharging or deep discharging.

Equipped with soft-start functionality and short-circuit protection, the UPS prevents sudden inrush currents and ensures a smooth shutdown mechanism in case of faults, safeguarding connected equipment.

The integrated LCD display and communication interfaces (RS-232) provide real-time monitoring of input/output voltage, battery status, and load conditions for enhanced control and diagnostics.

Ideal for IT infrastructure, industrial automation, medical equipment, telecom networks, banking and various other applications, the Enventa 1-Phase Online UPS is a reliable, high-efficiency power backup solution, ensuring seamless power continuity and equipment protection.

Input

Charger SCR (HT-11 Series) | IGBT (HT-11 i Series)
Nominal Input Voltage220/230V/240V ± 10% -15%
Input Frequency50Hz +/- 6%
Input Power Factor0.85 (HT-11 Series) | 0.95 (HT-11 i Series)

Output

Nominal Output Voltage220/230V/240V (Factory Settable) +/-1% Static (L-N)
WaveformPure Sine Wave
Frequency50Hz +/- 0.1% in Free Running Mode
THD<2% at 100% Linear Load, <5% at 100% Non-Linear Load
Crest Factor5:1 (Can be Tailored for Higher Crest Factor Requirements)
Load Power Factor0.8 (HT-11 Series) | 0.9 to Unity (HT-11 i Series)
Overload Capacity125% for 60 seconds, 110% for 10 minutes
Change Over Time0 sec

Battery

Nominal Battery Voltage VDC120V/144V/180V/192V
TypeSMF/VRLA/Ni-CD and Li-Ion
Charging Time8-10 Hours Typical

Indication

LCDLine Input, Load on Bypass, Inverter on, Battery Level Graph, Load Level Graph

Protections

Overload ProtectionAvailable
Short Circuit ProtectionAvailable
Common Mode EMI/ RFI AttenuationOver 100Hz to 30MHz Range
Phase Lock Loop MechanismSynchronization with Mains

General

ControllerMicro-controller (HT-11 Series) | DSP Controlled (HT-11 i Series)
EfficiencyUp to 85% (HT-11 Series) | Up to 94% (HT-11 i Series)
CoolingForced Air Cooling
CommunicationWindows Compatible Serial Interface via DB9 Connector for UPS Monitoring
Transfer timeMains Mode to Battery Mode: 0 ms Inverter Mode to Bypass Mode: 4 ms (Typical)
Operating Temperature0°C ~ 60°C
Storage Temperature-25°C ~ 55°C (without batteries)
OptionalsRMP - Remote Monitoring Panel RS-232 Interface, SNMP Protocol Battery Cabinets

Download Now to make an informed decision and ensure uninterrupted power for your critical operations.